Danh mục sản phẩm
Hỗ trợ trực tuyến
02633.602.435
0912.934.349
Kết nối với chúng tôi
Thống kê truy cập
- Đang online 0
- Hôm nay 0
- Hôm qua 0
- Trong tuần 0
- Trong tháng 0
- Tổng cộng 0
Mô hình đào tạo cấp cứu trẻ sơ sinh
GD/ACLS1400
Trung Quốc
12 tháng
Model: GD/ACLS1400
Hãng sản xuất: General Doctor
Tiêu chuẩn: ISO
LH 02633.602.435
GD/ACLS1400 is the world leading man-machine interaction infant ACLS training simulation system, can simulate real emergency scenes and all the related signs of emergency patient, such as: pupil states, artery pulse, heart rhythm, heart and lung auscultation sound, etc. All the clinical emergency measures such as defibrillation, pacing, CPR, drug therapy, etc, and real clinical emergency instrument can be acted on the system. The manikin would show different vital signs change according to different rescue measures. Open case editing function allows lecturer edit required emergency cases according to clinical practice and teaching requirement for students’ training use. Interactive internet features can implement whole students teaching; lecturer can acquire students’ operation data easily and timely give correction and guidance.
Serviceable group:
Post-graduate, interns, doctors, anaesthesia doctor, emergency center doctors, field ambulance staff, advanced study doctors, nurse;
Serviceable range:
Clinical teaching, physician, various assessment and emergency knowledge popularity.
Implement standard: AHA (American Heart Association) 2015 guideline for CPR and ECC
Features:
★ This sign indicates that the functions can be run only when the manikin is used with the optional accessories
Head and neck:
1. Normal, dilated pupil;
2. Airway management: realistic mouth, nose, tongue, gum, throat, esophagus, epiglottis, trachea, tracheal ring ; can practice tracheal intubation via mouth or nose, sputum suction; oxygen inhaling; may monitor airway intubation and umbilical vein catheterization, show correct and wrong intubation; there is prompt for wrong tracheal intubation; only right chest rise can be observed due to excessive intubation position;
3. Gastric intubation: detect tube position via auscultation; inserting gastric tube for gastrointestinal decompression, nasal feeding, gastric lavage, etc.
Chest and abdomen:
1. Pneumothorax puncture extraction, pleural effusion extraction training;
2. Auscultation sound: include heart sound, breath sound, bowel sound, of which the normal heart sound and breath sound can be adjusted according to the monitor HR and respiratory rate;
3. CPR training: Support multiple ventilation ways: mouth to mouth, mouth to nose, BVM to mouth; can monitor inflation times and frequency, compression time, frequency and depth; judge the ratio of artificial breathing and chest compression;
★ Real defibrillation and pacing: Achieve real defibrillation and pacing by using with real defibrillating pacer(prepared by user-self);
★ ECG monitoring: Be used with real ECG monitor (prepared by user-self) to realize ECG monitoring;
★ Simulative ECG monitoring should be used with GD/J115 multi-parameter simulation of ECG to achieve the function of monitoring ECG.
Limbs:
1. Venous transfusion/puncture, arm veins include and Scalp vein includes.
2. Umbilical care: Practice ligature of umbilical cord, umbilical vein catheterization;
3. Bone marrow puncture: Effusion of simulative bone marrow prompts proper tibial puncture; can inject into drugs and practice transfusion;
4. BP measurement training
Software:
1. Vital signs monitoring: spontaneous breath; simulate femoral artery, umbilical artery pulse; heart rate, cardiac rhythm, crying, hiccupping, BP, saturation of blood oxygen, ABP, mixed cyanosis, central cyanosis, peripheral cyanosis, amniotic fluid, muscular tension, convulsion, reflection, spontaneous movement and general paralysis; can perform Apgar score;
2. ECG, emergency scenes and cases are available in the system;
3. Neonatal ACLS emergency script editor is used to edit neonatal emergency cases and simulate emergency scenes;
4. Neonatal ACLS emergency script training software
5. Perform PETCO2: confirm tracheal intubation position and monitor the effectiveness of resuscitation operation
Standard components:
1. Intelligent ACLS Neonate Manikin
2. GD/HS7 BP Training Equipment
3. Heart and Lung Auscultation Simulator Set
4. GD/XD1000N ECG Generator
5. GD/CC999N Defibrillator Converter
6. BVM, Stethoscope, Laryngoscope, Tracheotomy tube, Infusion set.
7. Emergency System Controller
8. Medical Air Compressor
Optional accessories:
1. Computer
Bình luận