Hỗ trợ trực tuyến

02633.602.435

02633.602.435

0912.934.349

0912.934.349

Kết nối với chúng tôi

Thống kê truy cập

  • Đang online 0
  • Hôm nay 0
  • Hôm qua 0
  • Trong tuần 0
  • Trong tháng 0
  • Tổng cộng 0
Mô hình điều dưỡng mô phỏng dấu hiệu lâm sàng

Mô hình điều dưỡng mô phỏng dấu hiệu lâm sàng

(1 đánh giá)

GD/10000

Trung Quốc

12 tháng

Model:GD/10000

Hãng sản xuất: General Doctor

Tiêu chuẩn: ISO

LH 02633.602.435

The product is developed with the efforts of both company scientific and technical personnel and mechanic in factories. It is an interdisciplinary, high-intelligent and lifelike simulation system with full functions. Simulated human can simulate different clinical signs, medical treatments and relevant nursing procedures of emergency department, internal medicine and surgical department. It provides services for clinical diagnosis, collection of medical history, laboratory examination and auxiliary examination and a series of clinical procedures of clinical diagnosis,  scheming treatment methods, taking nursing measures.

The characteristics of GD10000:

Wireless control- simulated human built-in wireless remoter, which is completely controlled by wireless network handwriting tablet computer.

Lifelike anatomy- simulated human has the body structure and appearance of Asian adult. Precise anatomic structures and obvious anatomic landmark.

Comprehensive covered subjects -  diagnosis and treatments of different diseases, such as diagnostics, emergency department, internal medicine, surgical department, etc.

Simple operation - simulated human can lie one his back or his side, also he can sit.  Preset cases of illnesses and projects are convenient for users to do practices and examinations.

Portable -simulated human built-in battery supply, which avoids the troubles of wires. It is more lifelike and more flexible.

Cost-effectiveness - enjoy services of low cost and high quality. 

Application scopes of GD10000:

Available subjects: emergency departments; cardiovascular medicine, respiratory medicine, gastroenterology,  department of nephrology, hematology, department of endocrinology, department of internal neurology, department of rheumatology and immunology; forensic surgery, neurosurgery, thoracic surgery, urinary surgery, department of orthopedics.

Applicable Users: clinical inters, clinical doctors from various departments, medical students, clinical paramedics , emergency care personnel in different areas

Available range: clinical teaching in medical colleges and schools, clinical teaching in hospitals, private practice training, all kinds of examinations and operation training of emergency care personnel.

Manual instruction:

Safety precautions: please read the following precautions before the application of this system.

1. Safe electricity

(1)Use auxiliary power supply, no recommendation of other power line.

(2)Do not overload the accessory power supply

(3)The product must be equipped with input power supply with earth wire. Ensure the landing and polarization is valid.

(4)Please keep away from the electromagnetic field when using and preserve the product 

(5)Please turn off and reboot the system if encounter any malfunction caused by power supply flutter or  electromagnetic interference 

(6)Do not leave any fluid on the surface or the inner part of the product.

(7)Do not use the system in the rain. The usage of water is only limited in the the supported functions mentioned in the manual instructions.

(8)Do not use any chemical solvents to clean the elements of the system. Only clean water and dilute liquid soap can be used.

2. Safety of simulated human

(1)Do not dismantle the assembled parts of simulated human without permission.

(2)   Invasive operation is available only in accordance with the description supported in the manual instruction 

(3)Ensure that the simulated human are settled in a stable and solid platform to avoid the operational personnel being hurt.

(4)Do not let foreign matters get into the airway(except gases), save for little lubricant.

(5)When moving the simulated human, do not drag the limbs and drop it. Handling with care and moving smoothly are recommended.

(6)Do not use marker pen and pencil to scribble on the skin of simulated human. These marks cannot be eliminated.

(7)Do not use propanol ethyl carbinol and iodine preservative. These products will spoil or stain the skin of model.

(8)Wrapping model with printed matters like newspaper is prohibited.

 

Product function and operating instructions:

1. Head (1)  Simulate pupilla. The sizes of pupilla can be adjusted. Bilateral pupilla both have light reaction directly or indirectly. And they can be controlled respectively.

(2) Simulated human can blink both of his eyes

(3) Wireless inquisition. Unique dialog function between doctors and patients and inquisition practices are available. Simulated human can articulate after touching the wireless microphone sensor on the head of the him. He can also ask some questions, describe his chief complaint, conditions and simulate coughs like a patient. He can imitate the whole procedure of inquisition. During the procedure of inquisition procedure, instructing teacher will simulate the patient and have a conversation with the simulated human.

2. pulses

(1) Genuine artery pulses, artery pulses can be palpated in bilateral carotid artery, bilateral brachial artery, bilateral radial artery, bilateral femoral artery, bilateral popliteal artery and bilateral arteriae dorsalis pedis.

(2) The strength of pulses change in accordance with vital signs. There are three states including strong, weak and zero.

3. Respiration 

(1) Simulated human has genuine autonomous respiration. There are rises and falls of thorax

(2) Simulated human has multiple respiration modes, rates and depths of respiration, which all can be adjusted.

4. Airway management

(1) Mouth intubation is available for simulated human. The positions and depths of intubation can be detected. Wrong intubation shall bring out the alarm warning sound.

(2) Be able to simulate edema of the tongue

(3) Gnathospasmus

(4) Laryngismus

(5) Stiff neck

(6) Pharyngeal edema

(7) Left and right bronchial obstruction

(8) Main airway obstruction

  (9) Cricothyrotomy and thyrocricocentesis

5. Voice prompts

(1) There are lots of voice prompts restored. Simulated human will make different voices in accordance with different states of illnesses. 

(2)The volume of sounds and other settings can be operated through software.

6. Auscultation

(1) Varieties of respiratory auscultation, breath sounds and respiration are synchronous. Bilateral independent breath sounds can be respectively controlled.

(2) Varieties of cardiophony, cardiac sounds and heart beats are synchronous.

(3) Bowel sounds auscultation

(4) Auscultation of vascular accentuated

7. Blood pressure

(1) Intimate taking blood pressure through hamnatodynamometer. Auscultate through real stethoscope.(2) Real Korotkoff can be heard in the process of measurement. 

Monitor of vital signs:

Pulses, blood pressure, blood oxygen and ECG monitoring, etc.

12-lead ECG monitoring. Lots of ECG data have been stored in the system. Real 12-lead ECG monitoring can be conducted. Being able to simulate 12-lead ECG of several kinds of heart diseases. Software interface can display multiple leads.

Emergency treatment:

Cardio-pulmonary resuscitation: The treatment will be operated in accordance with the standards in  Cardio-pulmonary Resuscitation guidebook. Electronic monitoring airway opening, air blow volume,  air blow rate,  air blow times, compression locations, compression times, compression depths and rates all can be shown on the computer after being collected by sensors. And the system will judge whether the operation is right automatically.

Support real defibrillation, simulated defibrillation and cardiac pacing. (Simulated defibrillation operation can refer to J880 manual book)

Drug administration

Intramuscular injection: Bilateral deltoid hypodermic injection, lateral femoral intramuscular injection and intramuscular injection

Intravenous injection: bilateral Arm intravenous injection.

Right arm drug identification system: provide with over 30 kinds of drug labels. Scan he drug labels on the lower part of right arm, near finesse, drug name, doze and method of drug administration scanned will be shown on software.

Use real injection pump and infusion pump. Precise doze for special patient has been realized. System can detect the operation of injection and  infusion pump.

Pneumothorax puncture

Pneumothorax puncture should be done in the second intercostal of bilateral umidclavicular line.

There is “Di” prompt sound when puncture is successful.

Thoracentesis and drainage

(1)Thoracentesis and drainage should be done in the fifth intercostal of left midaxillary line. Draw out gas when succeed in puncture.

There is “Di” prompt sound when puncture is successful.

Paracentesis pericardii

Paracentesis pericardii should be done in the fifth intercostal of the inner side of  border of cardiac dullness.

There is “Di” prompt sound when puncture is successful.

Neurologic examination

(1)Knee reflex: simulated human lies on his back. The examiner holds the knee-joint and make it curve at the angle of about 120° with left hand. Knock quadriceps femoris under patella with the percussion hammer on right hand, which can cause calf stretch. There are five states, including no response, weak, normal, active and clonus.(2) nski syndrome: simulated human lies on his side with his legs straight. Use a prod to touch the lateral border of sole to little toe beside the footing and turn to interior from back to front. Positive reaction will be hallux dorsiflexion, other toes fan out. There are normal and abnormal states.Oppenheim syndrome: examiner uses big toe and index finger top-down sliding press the shin bone anterior border of tibia of simulated human. Positive reaction is the same as Babinski syndrome. There are normal and abnormal states.

15. Basic nursing functions

(1)Upper and lower fixed dentures, oral care is available

(2)Basic nursing operations are available, like washing face, washing head, eyes and ears cleaning.

(3)Four limbs are flexible to be bent from left to right and top-down. Head, neck and  articulationes mandibularis can be moved flexibly. Nursing operations like dressing and changing clothes, binding up,  and fixation of fracture are available

(4)Oxygen therapy is available. Multiple giving oxygen methods (oxygen provision via nasal canula, oxygen provision via masks, etc. ), Oxygen concentration can be adjusted accordingly.

(5)Insertion of nasogastric tube: gastric lavage and gastrointestinal decompression operation are available.

(6) Clyster practice, nursing of colon anastamosis and rectum of simulated human are available.

(7) Catheterization operation can be practiced

16. Case training/examination

(1)Emergency department: built-in multiple emergency cases of illness, independent cases of illness edit unit, editable cases when needed by customers.

(2)Internal Medicine: cases of cardiovascular, respiration, digestion, kidney, Hematology,  Endocrine, neurology, Rheumatoid immune. Simulated human can diagnose cases of different departments, laboratory examination and therapeutic measures.

(3)Surgery: including common cases of illness of general surgery, neurosurgery,  thoracic surgery, urinary surgery and orthopedics. Simulated human can diagnose cases of different departments. Apart of surgery operations could be observed through video.

17. Others 

(1) External genitals of females and males could be interchanged.

(2) Cyanosis

Đánh giá sản phẩm

Bình chọn sản phẩm:

Bình luận

Sản phẩm cùng loại

Top

   (0)